Modbus TCP

Polls holding registers and coils on the meters, drives, and PLCs that already run your plant.

The Modbus TCP connector polls the devices industrial sites have relied on for decades: power meters, variable-frequency drives, PLCs, and sensor gateways. It reads holding and input registers and coil states on a schedule you set per device, applies your register map to turn raw words into named, scaled values, and emits each reading as a governed event with device, register, and timestamp.

Modbus TCP carries no authentication in the protocol, so the connector runs read-only under this listing and reaches only the unit IDs and register ranges on its allow-list, with access scoped at the network layer. It is available now: built and maintained by Fibric, and wired with a Fibric deployment engineer through the early-access program.

Kind
Connector
Category
Sensing & telemetry
Publisher
Fibric
Availability
Available now
Sold by
Fibric
Support
Developed and supported by Fibric

Authentication

Modbus TCP is unauthenticated by design, so access is scoped at the network layer and constrained by the connector's per-device register allow-list.

What it reads

  • Power meter readings: kW, kWh, voltage, current, power factor
  • Drive telemetry: speed, torque, fault codes, run hours
  • PLC register values and coil states on the polling schedule you define

What it can do

This is a sensing source: it reads, it does not write. Operators act through the write-capable connectors alongside it.

Requirements

  • IP reachability to each Modbus TCP device or gateway
  • A register map (address, type, scaling) for the points you want read

Works with

Peak DemandOperator Shaves peak demand without anyone noticing: pre-cools, stages loads, and respects every comfort and safety guardrail you set. Available now Predictive MaintenanceOperator Hears the equipment going wrong before it fails. It reads vibration and runtime, predicts the fault, and opens the work order early. Available now Exception RoutingOperator Clears the exception before it stalls the line, rerouting work and dispatching the fix the moment flow breaks on the floor. Available now PLC Command BridgeConnector Sends vetted commands to programmable controllers on the line. Idempotency keys make a re-sent instruction a safe no-op, never a double. Available now OPC UAConnector The industrial standard for shop-floor data: browses the address space, subscribes to nodes, and keeps the model in sync. Available now